Expect
reliable results
with
George King Bio-Medical, Inc. Coagulation Factor Deficient Plasmas.
These quality plasmas are from human
donors with congenital
deficiencies and are most like your patient. The plasmas are
guaranteed to meet our strict quality control standards.
|
q
Fresh frozen plasmas
from HUMAN donors |
|
q
Donors have monospecific
congenital deficiency |
|
q
Most like your patient
matrix intact |
q
Substrate quality for
use in factor assays
|
| Factor I Deficient
Plasma (Afibrinogenemia)
|
top |
Consistent Quality
Control for Fibrinogen Assays
Factor
I Deficient plasma is drawn from a human donor with
afibrinogenemia and has very low levels of fibrinogen.
Recommended storage for this fresh frozen
plasma is -70°
C. Factor I Deficient
Plasma is tested and found non-reactive for HIVand HBsAg. |
| Product
|
Product
No. |
Size |
| Factor
I Deficient Plasma |
0100 |
1.0 mL
vials |
|
Factor II Deficient
Plasma
|
top |
|
Like Your Patients
Plasma |
| Factor
II Deficient plasma is drawn from a human donor with
a congenital deficiency. It is the quality necessary for use as
a substrate. Recommended storage for this fresh frozen
plasma is -70°
C. Factor II Deficient
Plasma is tested and found non-reactive for HIV and HBsAg. |
| Product
|
Product
No. |
Size |
| Factor
II Deficient Plasma |
0200 |
1.0 mL
vials |
|
Factor V Deficient
Plasma |
top |
|
Quality You Can
Count On |
| Factor V Deficient plasma
is drawn from a human donor with a congenital deficiency
assaying at <1% activity. The plasma is suitable for use in APC
resistance assays as well as Factor V assays. Recommended storage for this fresh frozen
plasma is -70°
C. Factor V Deficient
Plasma is tested and found non-reactive for HIV and HBsAg. |
| Product
|
Product
No. |
Size |
| Factor
V Deficient Plasma |
0500 |
1.0 mL
vials |
|
Factor VII Deficient
Plasma |
top |
|
Optimize the Performance
of Your Assays |
| Factor
VII Deficient plasma is drawn from a human donor
with a congenital deficiency and has <1% activity.
Recommended storage for this fresh frozen
plasma is -70°
C. Factor VII Deficient
Plasma is tested and found non-reactive for HIV and HBsAg. |
| Product |
Product
No. |
Size |
| Factor
VII Deficient Plasma |
0700 |
1.0 mL
vials |
|
Factor VIII Deficient
Plasma
|
top |
|
Reliable, High
Quality
Substrate |
| Factor
VIII Deficient plasma is drawn from a human donor with a
congenital deficiency and has <1% activity. Recommended
storage for this fresh frozen
plasma is -70°
C. Factor VIII Deficient
Plasma is HIV and HBsAg negative. |
| Product |
Product
No. |
Size |
| Factor
VIII Deficient Plasma
|
0800 |
1.0 mL
vials |
Factor IX Deficient
Plasma
|
top |
| Dependable Substrates
for Factor Assays |
| Factor
IX Deficient plasma is drawn from a human donor with a
congenital deficiency and has <1% activity. Recommended
storage for this fresh frozen
plasma is -70°
C. Factor IX Deficient
Plasma is HIV and HBsAg negative. |
| Product |
Product
No. |
Size |
| Factor
IX Deficient Plasma
|
0900 |
1.0 mL
vials |
Factor X Deficient
Plasma
|
top |
|
Discover the Difference |
| Factor X Deficient plasma
is drawn from a human donor with a congenital deficiency
and has <1% activity. Recommended storage for this fresh frozen
plasma is -70°
C. Factor X Deficient
Plasma is tested and found non-reactive for HIV and HBsAg. |
| Product |
Product
No. |
Size |
| Factor
X Deficient Plasma |
1000 |
1.0 mL
vials |
Factor XI
Deficient Plasma
|
top |
|
Experience
Quality without Compromise |
| Factor
XI Deficient plasma is drawn from a human donor with a
congenital deficiency. The
factor XI activity is <1%. Recommended storage for this fresh
frozen
plasma is -70°
C. Factor XI Deficient
Plasma is non-reactive for HIV and HBsAg. |
| Product |
Product
No. |
Size |
| Factor
XI Deficient Plasma |
1100 |
1.0 mL
vials |
Factor XII Deficient
Plasma
|
top |
|
The Best Choice for
Substrates |
| Factor XII Deficient
plasma is drawn from a human donor with a congenital
deficiency. This plasma assays at <1% activity.
Recommended storage for this fresh frozen
plasma is -70°
C. Factor XII Deficient
Plasma is tested and found non-reactive for HIV and HBsAg. |
| Product |
Product
No. |
Size |
| Factor
XII Deficient Plasma |
1200 |
1.0 mL
vials |
Factor XIII Deficient
Plasma
|
top |
|
Reliable Results |
| Factor XIII Deficient plasma
is drawn from a human donor with a congenital deficiency.
No FSF is present in this plasma.
Recommended storage for this fresh frozen
plasma is -70°
C.
Factor XIII Deficient
Plasma is tested and found non-reactive for HIV and HBsAg. |
| Product |
Product
No. |
Size |
| Factor
XIII Deficient Plasma
|
1300 |
1.0 mL
vials |
Von Willebrand Trait
Plasma Mild
|
top |
|
A Clear Choice
When Only
the Best Will Do |
| Mild
von Willebrand Trait is drawn from a human donor that
has a mild bleeding diathesis. Recommended storage for this fresh frozen
plasma is -70°
C. Mild von Willebrand Trait
Plasma is tested and found non-reactive for HIV and HBsAg. |
| Product |
Product
No. |
Size |
| vWd Trait Plasma - Mild |
1400-M |
1.0 mL vials |
Von Willebrand Trait
Plasma Severe
|
top |
|
When Quality Matters |
| Severe
von Willebrand Trait is drawn from a human donor that
has markedly abnormal levels of factor VIII and vWd factor. Recommended
storage for this fresh frozen
plasma is -70°
C. Severe von Willebrand Trait
Plasma is tested and found non-reactive for HIV and HBsAg. |
| Product |
Product
No. |
Size |
| vWd Trait Plasma - Severe |
1400-S |
1.0 mL vials |
Kininogen Deficient
Plasma
|
top |
|
(Currently Unavailable) |
| Kininogen
Deficient Plasma is drawn from a human donor with a
congenital deficiency. Screening
schemes for kininogen testing are available. Recommended storage
for this fresh frozen
plasma is -70°
C. Kininogen Deficient
Plasma is tested and found non-reactive for HIV and HBsAg. |
| Product |
Product
No. |
Size |
| Kininogen Deficient Plasma |
1600 |
1.0 mL vials |
Prekallikrein Deficient
Plasma
|
top |
|
Esoteric Plasmas
Readily
Available |
| Prekallikrein Deficient Plasma is drawn from a human
donor with a congenital deficiency. Detailed technical
information is available. Recommended storage for this fresh
frozen
plasma is -70°
C. Prekallikrein Deficient Plasma is tested and found non-reactive for
HIV and HBsAg. |
| Product |
Product
No. |
Size |
| Prekallikrein Deficient Plasma |
1700 |
1.0 mL vials |
Factor VIII Deficient
Plasma with Inhibitor
|
top |
|
Select the Best |
| Factor VIII Deficient Plasma
with Inhibitor is drawn from a human donor demonstrating
a specific inhibitor to factor VIII. Plasmas are available with a variety of Bethesda Unit titers.
Recommended storage for
this fresh frozen
plasma is -70°
C. Factor VIII
Deficient Plasma with Inhibitor is tested and found non-reactive for
HIV and HBsAg. |
| Product |
Product
No. |
Size |
| Factor
VIII Deficient Plasma w/Inhibitor |
1800 |
1.0 mL
vials |
EVALU-VIII Set |
top |
| Evaluate Every Part of
your Factor VIII Curve |
| Evalu-VIII
Set contains five assayed plasmas with varying levels of factor VIII
activity. Plasmas should be used as factor VIII controls.
Recommended storage for these fresh frozen
plasmas is -70°
C. Plasmas in this set are
tested and found non-reactive for HIV and HBsAg.
|
The set includes:
| Quantity |
FVIII Level |
| 3
X 1.0 mL |
Normal
|
| 3 X 1.0 mL |
Borderline |
| 3 X 1.0 mL |
Mild |
| 3 X 1.0 mL |
Moderate |
| 3 X 1.0 mL |
Severe |
| Product |
Product
No. |
Size |
| Evalu-VIII
Set |
9300 |
15 x